NAFFCO showcases in Intersec 2017

NAFFCO, the world’s main producer and provider of life security options exhibits at Intersec 2017, the world’s largest and most comprehensive trade and networking exhibition for the Security and Safety industries.
A leading producer and provider of life safety options, NAFFCO, the founding sponsor of Intersec is presenting the latest products and tendencies in security and safety focusing on its smart technologies and improvements. Intersec 2017 is being held from 22nd to twenty fourth January on the Dubai International Convention and Exhibition Centre, Dubai, UAE.
Recognizing Intersec as an international meeting platform, Eng. Khalid Al Khatib, Chief Executive Officer stated, “NAFFCO shall be standing out as a “one-stop-solution” source for all types of fireside protection methods. In the 1,439-sqm stand at Hall 6 of the Dubai World Trade Center, NAFFCO will showcase its wide range of state-of-the-art firefighting products together with heavy-duty hearth hoses and reels, fireplace suppression and protection methods, custom-made hearth cabinets, extinguishers, fire pumps fire-rated doorways, hearth alarms, CCTV systems, ambulances, rescue automobiles and hearth vans as properly as cellular hospitals and platform automobiles.”
In this year’s edition, NAFFCO highlighted, among other innovations and companies, the newly launched Pump Cloud, NAFFCO Automatic Fuel Filtration System, Aircraft Rescue Firefighting Vehicle (ARFFV), Emergency Lighting System, NAFFCO Training, New Eco-barid foam extinguisher for lithium batteries – a new sort of specialist hearth extinguisher for use on class D fires; SIL2 and so forth
Pump Cloud:
Considering the necessary position of fireside pump as the guts of firefighting system, it must be monitored round-the-clock to guarantee that it’s correctly working especially during emergencies. Pump Cloud is a contemporary and innovative system that enables 24/7 monitoring of fireplace pumps. It uses an interface unit linked with the hearth pump controllers and related sensors and tools within the Fire Pump room which in flip will send monitored signals to a particular modem that communicates with NAFFCO Desktop Managing system through 3G or GPRS, the place NAFFCO upkeep staff on standby are monitoring the pump 24 / 7 and ready for action.
NAFFCO Automatic Fuel Filtration System:
Fuel contamination is a serious cause of premature shutdown for standby engines, generator units, hearth pump engines, and different diesel engine help capabilities. Contamination starts as quickly as the tanks are filled and continues until the gas is used. As the size of storage period is increased, the chance of premature engine shutdown can also be increased due to clogged filter or excessive water entrainment.
The solution: NAFFCO Automatic Fuel Filtration System. It is a self-contained, stand-alone system that removes and prevents the build-up of water, sludge and contaminants in tanks. It stabilizes diesel and bio-fuels, eliminates microbial contamination to optimize and maintain fuel high quality. It is designed to satisfy NFPA necessities in maintaining and cleansing gas stored in fuel tanks in accordance with NFPA 20, NFPA 25, and NFPA one hundred ten.
Aircraft Rescue Firefighting Vehicle (ARFFV):
Also generally identified as the Fire Falcon 6, ARFFV is again in the Intersec this yr proudly showcasing its personal manufactured prototype of the falcon cabin which was successfully examined as per the internationally acknowledged testing E/ECE/324 and E/ECE/TRANS/505, Addendum 28, Regulation No. 29 with regard to protection of the occupants of the cabin. In the continuous effort to offer NAFFCO clients with confirmed and safe technologies, the necessities of the standard had been purposely exceeded and the falcon cabin demonstrated glorious power and impression properties. The roof power was tested with 13500 kg, which is 3500kg more than the regulation requirement and the entrance impression take a look at was carried out at 55 kJ, against the forty five kJ specified by the regulation.
Emergency Lighting System:
When the overall synthetic lighting fails, orientation must still be ensured in buildings even for guests. Accordingly, there are authorized provisions governing the gear and dimensioning of emergency lighting installations that shall be activated when there isn’t a mains voltage.
NAFFCO Provides the Intelligent Emergency Lighting Solution that ensures the protection and integrity of your emergency system with automated monitoring and reporting solution. All the merchandise Control Panel, Emergency Luminaires and equipment are totally tested and certified by British Standards Institution (BSI).
เกจวัดแรงดันดิจิตอลราคา & Grouping of Lights, Sets Maintenance Schedule, Generates auto Reports by using NAFFCO Addressable Emergency lighting monitoring contact panel. NAFFCO Emergency and Exit Lights are designed with newest LED know-how which is absolutely complying with green building idea.
Eco Barid Foam Fire Extinguisher for Class ABD and F
NAFFCO saved strain type Eco Barid foam extinguisher are multipurpose, ideal for fires involving unstable liquids and freely burning material corresponding to paper, cloth, wooden, furniture and cooking oil or fats fires (A,B,D and F classes of fire) and is appropriate for the use with most types of proportioning and discharge gadgets which performs excellently when used with CAF methods. ECO BARID FOAM is 100% environmental pleasant free from PFOA, PFOs and fluorine.
It is designed for fast fire knockdown by creating a film on the item of fire and along with this, it creates a cooling impact and acts like a fire sealant which helps to extinguish the hearth sooner and minimize re ignition. The environmental friendly elements within the foam focus have the deep impregnation functionality when used on combustible stable material fires which makes it near to inconceivable for re ignition. This is necessary when extinguishing deep-seated fires in wooden, paper, rubber, and different odd combustibles. It acts like a fire sealant when applied on combustible supplies.
SIL2
Safety Integrity Level (SIL2) is a measure of the reliability of a system to be in operation when a maximum threat and fault are analysed based on no of flooring, occupancy and in accordance to the information traces set by the Engineer or the Authority having Jurisdiction to maximize the reliability and effectivity of Life Safety, that’s the place you will want a SIL2 rated panel.
Why SIL2 supersedes the Normal Addressable Fire Alarm Panel?
Redundancy: CPU, I/O playing cards, Power Supply and Display obtainable on the panel to ensure the continual operation incase of one or more failures.
Hot–swap: CPU, I/O playing cards, Power Supply and Display can be replaced without switching off the panel, thus maintaining system safety and security performance.
Extreme reduction of false alarms below acceptable ranges out of one hundred indicators there’s a chance for just one fault.
High level of Reliability, Availability and Maintainability (RAM) for the software program and hardware of the system.
High tolerance and stability over electromagnetic noise.
NAFFCO Training
To enhance awareness and alleviate technical data on fireplace security requirements, NAFFCO presents training packages primarily based on three major aspects specifically:
Theory. Using the classroom environment our internationally accredited instructors teach NFPA guidelines and laws.
Practical. We provide hands-on coaching on all fireplace safety systems
Testing and certification. We provide NFPA certifications as properly as NAFFCO certifications
For extra data please go to www.naffco.com
Share

Scroll to Top